Analytical
Instrumentation and Equipment List
Gas Chromatography
- HP/Agilent
5890 Series II GC with dual FID, dual split/splitless injectors, 7673 liquid injection autosampler, 7694 Headspace
autosampler and data acquisition and control using
Agilent GC Chemstation software.
- HP/Agilent
5890 Series II GC with ECD, 7673 liquid injection autosampler and data acquisition
and control using Agilent GC Chemstation software.
- Shimadzu
2010 GC with FID, split/splitless injector, AOC 20i autosampler and
data acquisition via Agilent 35900D/E A/D
controller and Agilent GC Chemstation software.
- Shimadzu
2010 GC with FID, split/splitless injector, AOC 20i autosampler and
data acquisition via Agilent 35900D/E A/D
controller and Agilent GC Chemstation software.
- Perkin Elmer 8420 GC with NPD and G314V liquid injection
autosampler. Data acquisition and
control via SRI PeakSimple for Windows.
High Performance Liquid Chromatography
- Agilent 1100 Series
HPLC system with degasser, autosampler, quaternary pump, photodiode array
detector and data
acquisition and control using
Agilent LC Chemstation software.
- Agilent 1100 Series
HPLC system with degasser, autosampler, quaternary pump, photodiode array
detector and data
acquisition and control using
Agilent LC Chemstation software.
- Shimadzu 2010C HPLC
system with degasser,
thermostated autosampler, quaternary pump , variable UV detector and
data acquisition via Agilent
35900D/E A/D controller and Agilent LC Chemstation software.
- Shimadzu 2010C HPLC
system with degasser,
thermostated autosampler, quaternary pump , variable UV detector and
data acquisition via Agilent
35900D/E A/D controller and Agilent LC Chemstation software.
- Perkin Elmer Series
200 HPLC system with degasser, thermostated autosampler, quaternary pump, photodiode array detector and
data acquisition via Agilent
35900D/E A/D controller and Agilent LC Chemstation software.
- Perkin Elmer Series
200 HPLC system with degasser, thermostated autosampler, quaternary pump,
six column switching valve, photodiode array detector, electrochemical detector and data acquisition via Agilent 35900D/E A/D
controller and Agilent LC Chemstation software.
- Waters ILC-II
Ion/Liquid Chromatograph with degasser, binary pump,autosampler, column
oven, refractive index detector and conductivity detector. Data
acquisition and control via SRI PeakSimple for Windows.
- Jasco 980 HPLC system
with isocratic analytical pump, autosampler and variable wavelength
detector. Data acquisition and control via SRI
PeakSimple for Windows.
Additional
Detectors Available:
Perkin Elmer LS-30 Fluorescence/Luminescence Detector
SEDEX Evaporative Light Scattering Detector
Dionex Pulsed Ampeometric Detector
Waters 460 Electrochemical Detector
Gas Chromatography/Mass Spectrometry
- HP 5971 GC/MS system
with 7376B liquid injector autosampler and data acquisition and control
via Agilent GC/MS Chemstation software.
- HP 5970 GC/MS system
with HP 19395A headspace autosampler. and data acquisition and control
via HP GC/MS Chemstation software.
- HP
5972 GC/MS system with Tekmar 2000 purge & trap (dynamic headspace),
Tekmar 2016 autosampler and data acquisition and control via Agilent GC/MS
Chemstation software.
- LGC1050XL
high resolution HRGC/HRMS system with G311H autosampler instrument control
and data processing via ProLab Resources GC/MSsoftware.
- Varian
Saturn GC/MS (Ion Trap) system with split/splitless injector, Varian 8300 liquid
injector autosampler and Varian GC/MS software.
Liquid Chromatography/Mass Spectrometry
- Agilent
1100 Series LC/MS system with Agilent 1100 series capillary HPLC system
with degasser, thermostated autosampler, binary pump, photodiode array
detector, Agilent 1100 series mass spectrometer with electrospray
ionization source and control, data acquisition and processing by Agilent
LC/MS Chemstation software.
- Thermo TSQ 7000 triple
quadrapole LC/MS/MS system equipped with both ESI and APCI, operated under Thermo Xcalibur software, and
interfaced with an Agilent 1100 Series HPLC system with degasser,
autosampler, quaternary pump and photodiode array detector.
Atomic and EmissionSpectroscopy
- Perkin Elmer Aanalyst 300 flame atomic absorption
spectrophotometer configured with a six lamp turret, series 90/91 autosampler
and WinLab AAS software.
- Perkin Elmer 2380 atomic absorption spectrophotometer configured
with an AS40 autosampler, AS40 controller and HGA400 graphite furnace.
- Thermo GFWorkstation graphite furnace atomic absorption
spectrophotometer with DS2000 autosampler and Thermospec
AAS software.
- Thermo Atomscan inductively coupled plasma optical emission
spectrometer with Thermo Series 300 autosampler and Thermospec ICP software.
- Leeman Labs PS1000 sequential inductively coupled plasma optical
emission spectrometer system.
- Spectra HG34 cold vapor atomic absorption spectrophometer mercury
analyzer.
Optical Spectroscopy
- Perkin Elmer Spectrum 2000 research
grade FTIR & Raman spectrometer system with dual detectors for both
transmission and optical reflectance and HATR adaptor.
- Beckman DU68 UV-Visible
spectrophotometer.
- Shimadzu 1200 series UV-Visible
spectrophotometer.
Other Instrumentation
- Beckman Coulter 5500 series Capillary
Electrophoresis system with photo diode array detector and Beckman System
Gold software.
- Beckman Coulter 2050 series Capillary
Electrophoresis system with photo diode array detector and Beckman System
Gold software.
- Schott
Titroline Karl Fischer
autotitrator.
- Schott
Titroline 95 Series
autotitrator
- Schott
Titronic autotitrator.
- Abbe Refractometer.
- CEM Microwave digestion/extraction system.
- Malvern 3600 particle size analyzer.
- Various pH meters, conductivity meters,
ovens and balances.
|